How Is the Airflow Adjusted on Most Commercial Air Handlers?

Table of Contents

How Is the Airflow Adjusted on Most Commercial Air Handlers?

The airflow in most commercial air handlers is primarily adjusted by varying the speed of the supply fan motor. This speed modulation, achieved through techniques like variable frequency drives (VFDs) or stepped motor configurations, directly influences the volume of air circulated, thereby impacting heating, ventilation, and air conditioning (HVAC) system performance.

Understanding Airflow Adjustment in Commercial Air Handlers

Commercial air handlers (AHUs) are the workhorses of many building HVAC systems. They are responsible for taking air from the building (return air), conditioning it (heating, cooling, humidifying, dehumidifying), and then distributing it back into the building (supply air). Efficient operation relies heavily on properly adjusted airflow. Too little airflow can lead to inadequate heating or cooling, while excessive airflow wastes energy and can create uncomfortable drafts.

The goal of airflow adjustment is to match the AHU’s output to the building’s heating and cooling load requirements while minimizing energy consumption and maintaining optimal indoor air quality. Achieving this requires a multifaceted approach, considering factors like building occupancy, external weather conditions, and the specific design parameters of the HVAC system.

Methods of Airflow Adjustment

While several approaches exist, the most common methods for adjusting airflow in commercial air handlers involve manipulating the fan motor speed, damper positions, and, less frequently, fan pitch.

Adjusting Fan Motor Speed

This is the most prevalent method.

  • Variable Frequency Drives (VFDs): VFDs are electronic devices that control the frequency of the electrical power supplied to the fan motor. By varying the frequency, the motor speed can be precisely adjusted, allowing for fine-tuned airflow control. VFDs offer significant energy savings, especially when the HVAC system operates at partial load conditions. They are increasingly common in modern AHUs.
  • Stepped Motor Configurations: Older systems often employ stepped motors with multiple fixed speeds. Technicians can adjust the airflow by selecting a different motor speed via a switch or control panel. While less precise than VFDs, this method offers a simpler and more cost-effective solution.

Damper Control

Dampers are adjustable plates or louvers located within the ductwork of the AHU. They regulate the amount of air flowing through specific sections of the system.

  • Return Air Dampers: These dampers control the proportion of return air and fresh outdoor air entering the AHU. Adjusting these dampers impacts indoor air quality and energy consumption.
  • Discharge Dampers: Located at the outlet of the AHU, these dampers regulate the airflow to different zones within the building. Balancing these dampers ensures consistent temperatures throughout the building.

Adjusting Fan Pitch

In some cases, the angle (pitch) of the fan blades can be adjusted to alter the airflow. This method is less common than motor speed control and damper adjustment, typically requiring specialized tools and expertise. Changing the fan pitch is a more permanent adjustment and is usually performed during the initial commissioning of the AHU or during major overhauls.

Instruments and Techniques Used in Airflow Adjustment

Accurate airflow measurement is crucial for effective adjustment. Technicians utilize various instruments and techniques to determine the existing airflow and make informed adjustments.

  • Anemometers: These devices measure air velocity. Different types of anemometers exist, including vane anemometers, hot-wire anemometers, and pitot tubes.
  • Pitot Tubes: Pitot tubes measure both the total pressure and static pressure of the air stream. The difference between these pressures (dynamic pressure) is used to calculate air velocity.
  • Airflow Hoods (Balometers): These devices measure the airflow at a specific supply or return air register.
  • Duct Traverse: This involves measuring the air velocity at multiple points within a duct and averaging the readings to determine the total airflow.
  • Building Automation System (BAS) Monitoring: Many modern buildings incorporate a BAS that monitors airflow, temperature, and other parameters. Technicians can use the BAS to remotely monitor airflow and make adjustments as needed.

The Importance of Proper Airflow Adjustment

Proper airflow adjustment is essential for optimal HVAC system performance, energy efficiency, and indoor air quality. Failure to properly adjust airflow can lead to several problems:

  • Inadequate Heating or Cooling: Insufficient airflow can result in uneven temperature distribution and discomfort.
  • Excessive Energy Consumption: Operating the fan at unnecessarily high speeds wastes energy.
  • Poor Indoor Air Quality: Insufficient fresh air intake can lead to a buildup of pollutants.
  • Equipment Damage: Overworked fans can experience premature wear and tear.
  • Increased Operating Costs: All the above issues contribute to higher operating costs for the building.

Airflow Adjustment and Energy Efficiency

VFDs offer significant energy savings. By reducing the fan speed to match the actual heating and cooling load, the energy consumption of the fan motor can be dramatically reduced. The relationship between fan speed and power consumption is roughly cubic; therefore, a small reduction in fan speed can result in a substantial reduction in energy use. Furthermore, properly balanced airflow ensures that heating and cooling are delivered only where needed, preventing wasted energy in unoccupied areas.

Airflow Adjustment and Indoor Air Quality

Maintaining adequate fresh air ventilation is crucial for good indoor air quality. Airflow adjustment plays a vital role in ensuring that the correct amount of outdoor air is introduced into the building. This helps to dilute indoor pollutants, such as volatile organic compounds (VOCs), carbon dioxide, and allergens.

Airflow Adjustment and System Commissioning

Airflow adjustment is a critical part of the commissioning process for new HVAC systems. During commissioning, technicians verify that the system is performing according to design specifications. This includes measuring and adjusting the airflow to ensure that it meets the building’s heating and cooling requirements. Proper commissioning helps to prevent problems and ensure optimal performance throughout the system’s lifespan.

FAQs: Delving Deeper into Airflow Adjustment

Here are some frequently asked questions related to adjusting airflow in commercial air handlers:

1. What is the difference between CFM and static pressure, and how do they relate to airflow adjustment?

CFM (Cubic Feet per Minute) is a measure of airflow volume. Static pressure is the resistance to airflow in the ductwork. Airflow adjustment aims to achieve the designed CFM at the required static pressure. Increasing airflow typically increases static pressure, and vice versa. Understanding this relationship is critical for proper adjustment.

2. How often should airflow be checked and adjusted in a commercial air handler?

Airflow should be checked and adjusted at least annually as part of routine maintenance. More frequent checks may be necessary if there are changes in building occupancy, weather conditions, or if occupants report temperature discomfort. Recommissioning should be performed periodically (e.g., every 3-5 years) to ensure optimal performance.

3. What are the warning signs that the airflow in an air handler needs adjustment?

Warning signs include uneven temperature distribution, hot or cold spots, drafts, noisy operation, increased energy bills, and poor indoor air quality (e.g., stale air).

4. Can airflow be adjusted remotely through a building automation system (BAS)?

Yes, many modern BASs allow for remote airflow adjustment. Technicians can monitor airflow and adjust fan speeds and damper positions from a central control panel.

5. What are the potential risks of adjusting airflow improperly?

Improper airflow adjustment can lead to energy waste, temperature imbalances, poor indoor air quality, and equipment damage. It’s crucial to have qualified technicians perform airflow adjustments.

6. What certifications or qualifications should a technician have to perform airflow adjustments?

Technicians should ideally possess certifications from organizations such as the National Balancing Council (NBC), the Associated Air Balance Council (AABC), or similar recognized bodies. These certifications demonstrate competency in airflow measurement and adjustment techniques.

7. How does filter condition affect airflow, and should filters be considered during adjustment?

Dirty filters significantly restrict airflow. Filter replacement should be a standard step before airflow adjustment. Always ensure clean filters are in place before making any other adjustments.

8. How does duct leakage impact airflow and airflow adjustment?

Duct leakage reduces the amount of air delivered to the intended spaces. Airflow adjustment may compensate for leakage, but addressing the leaks themselves is crucial for energy efficiency and proper system performance.

9. Are there any specific airflow adjustment considerations for variable air volume (VAV) systems?

VAV systems require careful airflow adjustment to ensure proper operation of the VAV boxes. The AHU fan speed must be modulated to maintain sufficient static pressure in the ductwork, allowing the VAV boxes to effectively regulate airflow to individual zones.

10. What is the role of static pressure reset in optimizing airflow and energy efficiency?

Static pressure reset is a control strategy that adjusts the AHU fan speed based on the demand from the VAV boxes. By reducing the fan speed when the demand is low, static pressure reset minimizes energy consumption without compromising comfort.

11. How can airflow adjustment contribute to LEED certification or other green building initiatives?

Proper airflow adjustment is a key component of energy-efficient building operation and can contribute to earning points in LEED and other green building rating systems. Accurate airflow measurement and optimization demonstrate a commitment to sustainability.

12. What resources are available for learning more about airflow adjustment in commercial air handlers?

Organizations like ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) offer valuable resources, including standards, guidelines, and training courses on HVAC system design, operation, and maintenance, including airflow adjustment.